1#!/bin/sh
2# dpaa2-linkfix -- detect and recover the dpaa2 "ni" internal link-state desync,
3# and capture everything needed to find the actual defect.
4# Workaround for FreeBSD bug 279352 ("dpaa2 (dpni0 device): interface goes
5# catatonic periodically"). No upstream fix exists; PR open since 2024-05-27.
6#
7# dpaa2-linkfix event <ifname> called by devd on a link-state change
8# dpaa2-linkfix poll <ifname> called by cron as a safety net
9# dpaa2-linkfix dump <ifname> capture state only, change nothing
10#
11# THE BUG. The ni's internal link state goes DOWN without the driver re-issuing
12# DPAA2_CMD_MAC_SET_LINK_STATE (it is guarded by
13# `if (link_state != sc->link_state)` in dpaa2_ni_miibus_statchg()). ifconfig
14# still reports LOWER_UP and the switch still reports the port up, but no packets
15# pass. Only a real media transition resyncs it.
16#
17# WHY devd IS THE RIGHT HOOK. devd cannot see the fault itself -- no interrupt
18# means no if_link_state_change() means no devd event. But the fault is *created
19# during a real link transition*, which devd does see (bz@ captured "2 link states
20# coalesced" immediately before a wedge, PR 279352 comment 16). So we reconcile
21# the driver's internal link state against reality every time the link moves.
22# The cron poll is the safety net for a desync with no event at all (PR c17).
23#
24# THE LOOP HAZARD. Our own media flap emits LINK_DOWN + LINK_UP, which re-invokes
25# this script. Guarded three ways: an atomic mkdir lock, a self-inflicted quiet
26# period, and an hourly rate limit.
27#
28# DEBUG.log is the point of this script as much as the recovery is. We dump full
29# state BEFORE and AFTER the media flap, so the recovery itself is an experiment:
30# the before/after diff shows exactly which state the flap resynced.
31
32MODE=${1:-poll}
33IF=${2:-dpni0}
34UNIT=$(echo "$IF" | sed 's/^dpni//')
35
36SW=172.16.1.2 # switch, used only to verify recovery
37OOB=dpni1 # second, unaddressed link to the same switch
38SETTLE=4 # let the MC settle after a real transition
39QUIET=45 # ignore events for this long after our own flap
40MAX_PER_HOUR=4
41LOCK=/var/run/dpaa2-linkfix.$IF.lock
42QUIETF=/var/run/dpaa2-linkfix.$IF.quiet
43HIST=/var/run/dpaa2-linkfix.$IF.hist
44
45WORK=/var/tmp/ai/switch
46DEBUG=$WORK/DEBUG.log
47CURL=/usr/local/bin/curl
48NTFY=https://ntfy.sh/skunkwerks
49
50PATH=/sbin:/bin:/usr/sbin:/usr/bin:/usr/local/sbin:/usr/local/bin
51export PATH
52
53log() { logger -t dpaa2-linkfix "$IF/$MODE: $*"; }
54
55# Push a notification. Backgrounded and time-limited so a slow or dead uplink
56# can never delay the recovery. During a wedge the uplinks (dpni8/dpni9) stay
57# up, so this does get out.
58notify() {
59 [ -x "$CURL" ] || return 0
60 ( "$CURL" -s -m 10 \
61 -H "Title: r02 $IF dpaa2 bug 279352" \
62 -d "r02 $IF: $*" "$NTFY" >/dev/null 2>&1 & ) >/dev/null 2>&1
63 return 0
64}
65
66mc_state() {
67 sysctl -n "dev.dpaa2_ni.$UNIT.link" 2>/dev/null |
68 awk -F': ' '/Link State/{print $2}' | awk '{print $1}'
69}
70
71# DO NOT reintroduce an ifconfig call here. 2026-08-20: `ifconfig` is not a
72# read-only command on this board. Any invocation - even `ifconfig dpni0` -
73# sends a netlink RTM_GETLINK with NLM_F_DUMP (ifconfig_netlink.c:149), and the
74# kernel then runs get_operstate_ether() -> SIOCGIFMEDIA -> mii_pollstat() ->
75# MDIO on EVERY interface (netlink/route/iface.c:126). On r02 that is an
76# 8-PHY sweep of a shared memac MDIO bus, which is what generates the phantom
77# link transitions that wedge the DPMAC in the first place. This poll used to
78# do 288 such sweeps a day, and in event mode it was a positive feedback loop:
79# flap -> devd -> ifconfig -> more flaps.
80#
81# LOWER_UP cannot be read without causing the sweep: it is not a native FreeBSD
82# flag, it is synthesised at iface.c:315 from the operstate that the MDIO poll
83# just produced. So the test is dropped entirely and we gate on mc_state()
84# alone - which is the authoritative signal anyway, being the MC firmware's own
85# view, i.e. the thing that actually gates the datapath. False positives on a
86# genuine cable-out are bounded by the MAX_PER_HOUR rate limit below.
87#
88# See LOG.md §3c and CURRENT.md §8.
89
90# ---------------------------------------------------------------------------
91# Full state capture. $1 = label (e.g. "BEFORE-HEAL").
92# Everything here is read-only except the out-of-band ARP probe, which injects
93# raw frames on an unaddressed interface and changes no configuration.
94# ---------------------------------------------------------------------------
95dump() {
96 LABEL=$1
97 mkdir -p "$WORK"
98 {
99 echo
100 echo "================================================================"
101 echo "== $LABEL $IF $(date '+%Y-%m-%d %H:%M:%S') mode=$MODE"
102 echo "== uptime:$(uptime)"
103 echo "================================================================"
104
105 echo "---- 1. THE SIGNATURE: MC internal link state vs ifconfig ----"
106 echo "# Read ONLY the UP/DOWN word. '(IGNORE)'/'(VALID)' is a driver"
107 echo "# display bug (an always-zero reserved bit) and is always IGNORE."
108 sysctl "dev.dpaa2_ni.$UNIT.link" 2>&1
109 echo "---- sampled 3x, 1s apart, to see if it is flapping ----"
110 for i in 1 2 3; do echo " [$i] $(mc_state)"; sleep 1; done
111
112 echo "---- 2. ifconfig -m $IF ----"
113 ifconfig -m "$IF" 2>&1
114
115 echo "---- 3. INTERRUPTS: did the DPNI link-change IRQ actually fire? ----"
116 echo "# This is the crux of the upstream claim 'we do not see an"
117 echo "# interrupt for a link-state change'. Compare across dumps."
118 vmstat -i 2>&1 | grep -i "dpaa2\|dpni\|total" || echo "(none)"
119
120 echo "---- 4. all dpaa2_ni.$UNIT sysctls (incl. full stats) ----"
121 sysctl "dev.dpaa2_ni.$UNIT" 2>&1
122
123 echo "---- 5. dpaa2_mac objects ----"
124 sysctl dev.dpaa2_mac 2>&1 | grep -v "^dev.dpaa2_mac.[0-9]*.%" || true
125
126 echo "---- 6. link state of EVERY dpni (is only $IF affected?) ----"
127 for u in 0 1 2 3 4 5 6 7 8 9; do
128 S=$(sysctl -n "dev.dpaa2_ni.$u.link" 2>/dev/null |
129 awk -F': ' '/Link State/{print $2}')
130 R=$(sysctl -n "dev.dpaa2_ni.$u.link" 2>/dev/null |
131 awk -F': ' '/Link Rate/{print $2}')
132 # NOTE: this ifconfig triggers a full 8-PHY MDIO sweep (see the
133 # comment on mc_state()). Tolerated only because dump() runs when
134 # we are already wedged and the evidence is worth more than the
135 # extra dice roll. Do not call dump() speculatively.
136 F=$(ifconfig "dpni$u" 2>/dev/null |
137 sed -n '1s/.*flags=[0-9a-fx]*<\([^>]*\)>.*/\1/p')
138 echo " dpni$u internal='$S' rate=$R flags=$F"
139 done
140
141 echo "---- 7. PHY / miibus ----"
142 sysctl dev.vscphy 2>&1 | grep -vE "%(pnpinfo|location|parent|driver)" | head -40
143
144 echo "---- 8. reachability over $IF ----"
145 ping -c 3 -t 3 "$SW" 2>&1
146
147 echo "---- 9. reachability over $OOB (OUT OF BAND, raw ARP, no config) ----"
148 echo "# $OOB is link-active to the same switch but unaddressed, so it"
149 echo "# bypasses the IP stack entirely. If the switch answers here but"
150 echo "# not on $IF, the fault is confined to $IF's DPMAC/datapath."
151 if [ -x /usr/sbin/tcpdump ] || [ -x /usr/bin/tcpdump ]; then
152 tcpdump -i "$OOB" -n -c 4 -s 128 arp > "$WORK/.oob.$$" 2>&1 &
153 T=$!
154 sleep 1
155 python3 "$WORK/arpsend.py" "$OOB" 172.16.254.253 "$SW" 6 2>&1
156 sleep 3
157 kill $T 2>/dev/null; wait $T 2>/dev/null
158 cat "$WORK/.oob.$$" 2>/dev/null
159 rm -f "$WORK/.oob.$$"
160 fi
161
162 echo "---- 10. the servers ----"
163 for a in 2a02:1b8:10:205::6 2a02:1b8:10:205::7; do
164 echo " ping6 $a:"; ping6 -c 2 -i 1 "$a" 2>&1 | tail -3
165 done
166
167 echo "---- 11. neighbour / arp / route ----"
168 ndp -an 2>&1 | head -20
169 arp -an 2>&1 | head -20
170 netstat -rn -f inet6 2>&1 | grep -i "205::" || true
171
172 echo "---- 12. interface error counters ----"
173 netstat -idW 2>&1 | head -20
174 echo "---- mbufs ----"
175 netstat -m 2>&1 | head -8
176
177 echo "---- 13. recent kernel messages (link state changed / coalesced) ----"
178 dmesg 2>&1 | grep -iE "dpni|dpaa2|dpmac|link" | tail -30
179
180 echo "---- 14. is r02 still up to the world? (expected: yes) ----"
181 ping6 -c 2 -i 1 2606:4700:4700::1111 2>&1 | tail -3
182 birdc show protocols 2>/dev/null | head -15
183
184 echo "== END $LABEL =="
185 } >> "$DEBUG" 2>&1
186}
187
188# --- mode: dump only -------------------------------------------------------
189if [ "$MODE" = dump ]; then
190 dump "MANUAL-DUMP"
191 echo "appended to $DEBUG"
192 exit 0
193fi
194
195# --- guard 1: only one instance at a time (mkdir is atomic) ----------------
196if ! mkdir "$LOCK" 2>/dev/null; then
197 exit 0
198fi
199trap 'rmdir "$LOCK" 2>/dev/null' EXIT INT TERM
200
201# --- guard 2: ignore the events our own flap generates ---------------------
202if [ -f "$QUIETF" ]; then
203 AGE=$(( $(date +%s) - $(cat "$QUIETF" 2>/dev/null || echo 0) ))
204 if [ "$AGE" -lt "$QUIET" ]; then
205 exit 0
206 fi
207fi
208
209[ "$MODE" = event ] && sleep "$SETTLE"
210
211S=$(mc_state)
212
213# Breadcrumb, event mode only (~5/day given dpni0's flap rate). Without this a
214# healthy flap leaves no trace at all and we could not tell a working hook from a
215# silently broken one. It also gives us a local, timestamped flap log.
216if [ "$MODE" = event ]; then
217 log "link transition seen: internal=$S rate=$(sysctl -n dev.dpaa2_ni.$UNIT.link 2>/dev/null | awk -F': ' '/Link Rate/{print $2}')"
218fi
219
220# The signature: the MC firmware's internal view says DOWN. Keying on the
221# sysctl rather than on reachability means an unrelated outage can never trick
222# us into flapping a healthy interface. The former second term (ifconfig
223# LOWER_UP = yes) was removed on 2026-08-20 - see the comment on mc_state()
224# above; reading it was itself triggering the fault.
225if [ "$S" != DOWN ]; then
226 exit 0
227fi
228
229# --- guard 3: hourly rate limit -------------------------------------------
230NOW=$(date +%s)
231if [ -f "$HIST" ]; then
232 N=$(awk -v now="$NOW" 'now - $1 < 3600' "$HIST" | wc -l | tr -d ' ')
233 if [ "$N" -ge "$MAX_PER_HOUR" ]; then
234 log "SUPPRESSED, already healed $N times this hour; link may be genuinely dead"
235 notify "SUPPRESSED - $N heals this hour, link may be genuinely dead"
236 exit 0
237 fi
238 awk -v now="$NOW" 'now - $1 < 7200' "$HIST" > "$HIST.n" && mv "$HIST.n" "$HIST"
239fi
240echo "$NOW" >> "$HIST"
241
242log "bug 279352 signature: MC internal link state DOWN on $IF - healing"
243notify "WEDGED (MC internal link DOWN). Capturing + healing."
244
245# --- evidence BEFORE we change anything -----------------------------------
246dump "BEFORE-HEAL"
247
248# --- the fix: the sequence the maintainers validated ----------------------
249# 'none' or '10baseT/UTP', then back to auto. NOT 100baseTX (duplex mismatch
250# risk for no benefit).
251date +%s > "$QUIETF"
252ifconfig "$IF" media none
253sleep 3
254ifconfig "$IF" media autoselect
255sleep 8
256date +%s > "$QUIETF"
257
258S=$(mc_state)
259USED="media none"
260if [ "$S" != UP ]; then
261 log "still $S after 'media none', trying 10baseT/UTP (PR 279352 c16)"
262 ifconfig "$IF" media 10baseT/UTP
263 sleep 3
264 ifconfig "$IF" media autoselect
265 sleep 8
266 date +%s > "$QUIETF"
267 S=$(mc_state)
268 USED="media none, then 10baseT/UTP"
269fi
270
271# --- evidence AFTER: the diff against BEFORE-HEAL is the experiment -------
272dump "AFTER-HEAL (applied: $USED)"
273
274if ping -c 2 -t 3 "$SW" >/dev/null 2>&1; then
275 log "HEALED via '$USED': internal link=$S, switch reachable again"
276 notify "HEALED via '$USED'. internal link=$S. See DEBUG.log"
277else
278 log "HEAL FAILED via '$USED': internal link=$S, switch still unreachable."
279 log "mode 2/3 per LOG.md 3b - a reboot may be needed; media flap not enough"